Technical data
AirKompakt P0714 AirKompakt P0916 AirKompakt P1118 AirKompakt P1522 AirKompakt P1926Heating A7/W35
Heating power
8,000 kW
9,062 kW
11,200 kW
15,180 kW
19,650 kW
Electric power consumption
1,670 kW
1,950 kW
2,599 kW
3,677 kW
4,226 kW
COP
4,800
4,647
4,310
4,140
4,650
Heating A2/W35
Heating power
6,260 kW
6,996 kW
9,400 kW
13,500 kW
14,400 kW
Electric power consumption
1,610 kW
1,911 kW
2,473 kW
3,562 kW
3,891 kW
COP
3,890
3,660
3,800
3,790
3,700
Basic parameters
Refrigerant/charge
R290/1,2 kg
R290/1,3 kg
R290/1,7 kg
R290/2,2 kg
R290/2,49 kg
Maximum supply temperature
65C
65C
65C
65C
65C
Sound power level
61 db(A)
63 db(A)
66 db(A)
68 db(A)
69 db(A)
Scales
175 kg
180 kg
200 kg
210 kg
215 kg
Energy class – moderate climate, low-temperature installation
A++
A++
A++
A++
A++
Energy class – moderate climate, medium temperature installation
A++
A++
A++
A++
A++
Defrosting
Reverse circulation
Reverse circulation
Reverse circulation
Reverse circulation
Reverse circulation
Power supply
3x 400 V
3x 400 V
3x 400 V
3x 400 V
3x 400 V
External dimensions
Height (A)
1035 mm
1035 mm
1166 mm
1166 mm
1366 mm
Depth (B)
595 mm
595 mm
595 mm
595 mm
595 mm
Length (C)
1300 mm
1300 mm
1300 mm
1400 mm
1400 mm
Leg spacing, length (D)
1180 mm
1180 mm
1180 mm
1280 mm
1280 mm
Leg spacing, depth (E)
470 mm
470 mm
470 mm
475 mm
475 mm
Other dimensions
heating circuit connection diameter
1”
1”
1”
1 1/4”
1 1/4”
Location of the heating circuit connection – dimension F
32 mm
32 mm
32 mm
47 mm
47 mm
Location of the heating circuit connection – dimension G
177 mm
177 mm
177 mm
124 mm
124 mm
Location of the heating circuit connection – dimension H
247 mm
247 mm
247 mm
224 mm
224 mm
Location of condensate drain – dimension I
554 mm
554 mm
554 mm
570 mm
570 mm
Condensate drain location – dimension J
93 mm
93 mm
93 mm
94 mm
94 mm
Other parameters
Heating water temperature adjustment range
+20C up to +65C
+20C up to +65C
+20C up to +65C
+20C up to +65C
+20C up to +65C
Max. hot water temp. at outside temp. -7C
65C
65C
65C
65C
65C
Outside air temperature range for heat pump operation
-25C up to +40C
-25C up to +40C
-25C up to +40C
-25C up to +40C
-25C up to +40C
Number of compressors
1 piece
1 piece
1 piece
1 piece
1 piece
Maximum operating pressure of the heat pump’s central heating refrigeration circuit
24,5 bar
24,5 bar
24,5 bar
24,5 bar
24,5 bar
Air volume flow at maximum compression
3600 m3/h
4000 m3/h
5800 m3/h
6300 m3/h
7000 m3/h
Required water volume flow
1350 l/h
1640 l/h
1900 l/h
2500 l/h
3200 l/h
Maximum operating pressure of the central heating circuit
2,5 bar
2,5 bar
2,5 bar
2,5 bar
2,5 bar
Hermetic cooling system
Yes
Yes
Yes
Yes
Yes